American Wire Gauge Chart:

VIAIR recommends that you reference the chart below in order to
determine the length and gauge of wire when installing your compressor.

Download a PDF Version


AMERICAN WIRE GAUGE (AWG) FOR 12-VOLT CIRCUITS

TOTAL
AMPS
TOTAL LENGTH OF WIRE FROM BATTERY TO COMPRESSOR
5 Ft. 10 Ft. 15 Ft. 20 Ft.
5 Amps 16 AWG 16 AWG 16 AWG 14 AWG
10 Amps 16 AWG 14 AWG 12 AWG 10 AWG
15 Amps 16 AWG 12 AWG 10 AWG 10 AWG
20 Amps 14 AWG 10 AWG 10 AWG 8 AWG
25 Amps 14 AWG 10 AWG 8 AWG 6 AWG
30 Amps 12 AWG 10 AWG 8 AWG 6 AWG
40 Amps 12 AWG 8 AWG 6 AWG 6 AWG
50 Amps 10 AWG 6 AWG 6 AWG 4 AWG
60 Amps 10 AWG 6 AWG 4 AWG 4 AWG


AMERICAN WIRE GAUGE (AWG) FOR 24-VOLT CIRCUITS

TOTAL
AMPS
TOTAL LENGTH OF WIRE FROM BATTERY TO COMPRESSOR
5 Ft. 10 Ft. 15 Ft. 20 Ft.
5 Amps 16 AWG 16 AWG 16 AWG 16 AWG
10 Amps 16 AWG 16 AWG 16 AWG 14 AWG
15 Amps 16 AWG 16 AWG 14 AWG 12 AWG
20 Amps 16 AWG 14 AWG 12 AWG 10 AWG
25 Amps 16 AWG 12 AWG 12 AWG 10 AWG
30 Amps 16 AWG 12 AWG 10 AWG 10 AWG
40 Amps 14 AWG 10 AWG 10 AWG 8 AWG
50 Amps 14 AWG 10 AWG 8 AWG 6 AWG
60 Amps 12 AWG 10 AWG 8 AWG 6 AWG

Plumbing Diagrams:


VIAIR recommends that you reference the plumbing
diagrams below when installing your compressor.

Onboard Air Systems:



Plumbing Diagram